Sign In | Join Free | My himfr.com
Home > Radar Level Gauge >

HKD901 Anti-Corrosion RS485 Water Liquid IP67 Radar Level Transmitter

    Buy cheap HKD901 Anti-Corrosion RS485 Water Liquid IP67 Radar Level Transmitter from wholesalers
     
    Buy cheap HKD901 Anti-Corrosion RS485 Water Liquid IP67 Radar Level Transmitter from wholesalers
    • Buy cheap HKD901 Anti-Corrosion RS485 Water Liquid IP67 Radar Level Transmitter from wholesalers
    • Buy cheap HKD901 Anti-Corrosion RS485 Water Liquid IP67 Radar Level Transmitter from wholesalers

    HKD901 Anti-Corrosion RS485 Water Liquid IP67 Radar Level Transmitter

    Ask Lasest Price
    Brand Name : vacorda
    Model Number : HKD901
    Certification : CE/ISO9001
    Price : Negotiable
    Supply Ability : 110 Piece/Pieces per Week
    • Product Details
    • Company Profile

    HKD901 Anti-Corrosion RS485 Water Liquid IP67 Radar Level Transmitter

    HKD901 Anti-Corrosion RS485 Water Liquid IP67 Radar Level Transmitter



    Product type

    There are two types of HBRD901 rod radar antennas: 100mm and 200mm. When the takeover is longer, it will not seriously affect the measurement and will increase some blind spots.


    HKD901 Radar level

    advantagedisadvantage

    Resistance to slight condensation, suitable for corrosive environments with small flanges (minimum DN50) within 10m, small acid gas or steam in the tank


    HKD901 radar is not suitable when the temperature in the tank is high, sour gas or steam is large. The dead zone of HKD901 radar is generally less than 0.3m. It can only measure the environment of normal pressure, and can not add high temperature heat sink.

    High-frequency radar level gauge parameters

    temperature"The ambient temperature requirement is -30 ~ 65 ° C. If it is below -30 ° C, heat tracing is required.
    Process temperature range
    Solid standard type: -40 ~ 130 ℃
    High temperature type: -40 ~ 240 ℃ "
    applicationMeasurement of powder, granules, blocks and other solids; hydraulic and liquid conditions
    output signalRS485 output signal with single selection
    Explosion proof"Single-cavity intrinsically safe explosion-proof type: Exia IIC T6 Ga, when using on-site in explosion-proof occasions, it is required to install a safety barrier in the control room
    Double-chamber flameproof type: Exd IIC T6, no need for central control and no safety barrier when used in explosion-proof occasions. When on-site power is 220V, only dual-chamber radar can be selected
    "
    Protection classIP67
    power supply12-24VDC/220VAC

    Product parameters:

    Measuring range0~30 m
    Process connectionthread, flange
    Medium temperature-40 °C ~ 150 °C
    Process pressure0.1 ~ 4.0MPa
    Accuracy± 3mm
    Protection gradeIP67
    Frequency range6GHz, 26GHz
    Explosion-proof gradeExiaC T6 GaExib CT6 Gb
    Signal output4-20mA/HART (two / four), RS485/ Mod bus
    Typeguided wave radar, intelligent radar, 26 GH high frequency radar

    Detailed Images

    HKD901 Anti-Corrosion RS485 Water Liquid IP67 Radar Level Transmitter

    Sichuan VACORDA Instruments Manufacturing Co., Ltd. is a professional production-manufacturing enterprise specialized in designing, producing and marketing of instruments and apparatuses. Our company has been established for 21 years since 1997 to grow up to be a team of high-quality, united, hard-working and truth-seeking characters. Solid foundation has been established.

    HKD901 Anti-Corrosion RS485 Water Liquid IP67 Radar Level TransmitterHKD901 Anti-Corrosion RS485 Water Liquid IP67 Radar Level Transmitter

    According to different measurement principles, radar level gauges can be divided into two types. It is a radar level gauge that controls the liquid level, and its accuracy is generally about 10mm; the other is a radar level gauge, which is used for precise measurement and settlement, with an accuracy of 1mm. Structurally, it is divided into rod antenna, horn antenna and cable antenna, debugging, installing and using the analog signal output by the radar level gauge. The digital signal is superimposed on it by 4~20mADC to realize the compatibility of analog signal and digital signal, conforming to HART protocol. It can provide users with more attractive solutions, especially suitable for large fluctuations, condensation, suspension, viscous slurries, dirty media, and corrosive liquid level measurement. It has a continuous frequency self-calibration function to ensure stable measurement accuracy; it uses HART protocol for digital communication, and uses communication equipment or portable handheld devices to process liquid level variables; the output signal is an analog signal and a HART digital signal superimposed. Using the 4-20mAhar manual operator, the output signal can be divided into liquid level, calculated volume or standard volume; all configuration information and programs are stored in non-erasable memory. When the power is interrupted, all data can be restored; the frequency is continuously self-calibrated to ensure the accuracy of the level gauge.

    Quality HKD901 Anti-Corrosion RS485 Water Liquid IP67 Radar Level Transmitter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sichuan Vacorda Instruments Manufacturing Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category: