    Usa Standard Atex Water Sewage Electromagnetic Flow Meter For Liquid Propane

    Ask Lasest Price
    Brand Name : VACORDA
    Model Number : HKLD
    Price : $150.00 - $350.00 / Pieces
    Supply Ability : 200 Piece/Pieces per Month
    Certification : CE/TUV/ISO9001/SGS
    • Product Details
    • Company Profile

    Usa Standard Atex Water Sewage Electromagnetic Flow Meter For Liquid Propane

    Usa Standard Atex Water Sewage Electromagnetic Flow Meter For Liquid Propane


    HKLD type intelligent electromagnetic flowmeter is a fully intelligent electromagnetic flowmeter developed by our company using the most advanced technology at home and abroad. Its electromagnetic converter core adopts high-speed central processing unit. The calculation speed is very fast, the precision is high, and the measurement performance is reliable. The sensor adopts non-uniform magnetic field technology and special magnetic circuit structure, the magnetic field is stable and reliable, and the volume is greatly reduced, the weight is reduced, and the flowmeter is characterized by small flow.


    Application

    Due to its unique advantages, it is widely used in the fields of petroleum, chemical industry, steel, light industry, sewage processing, environmental protection, water conservancy project and pharmacy to measure the volume flow of the conducted liquid mediums, such as acid, alkali, salt solution and so on.


    Features

    1. No moving and blocked flow parts in the pipeline, almost no additional pressure loss in the measurement.

    2. Measurements results are independent of physical parameters, such as flow distribution, fluid pressure, temperature, density and viscosity.

    3. On-site modification of the measuring range available.

    4. LCD display, easy to use and simple to operate.

    5. Using SMD devices and SMT technology.

    Usa Standard Atex Water Sewage Electromagnetic Flow Meter For Liquid Propane


    Product Parameters

    Product Name

    Electromagnetic Flowmeter

    Repeatability error

    +/-0.1%

    Accuracy class

    0.5 class, 1.0 class

    Measured medium temperature

    Common rubber lining: -20~+60 ° c

    High temperature rubber lining: -20~+90 ° c

    PTFE lining: -30~+100 ° c

    High temperature vinyl lining: -30~+180 ° c

    Rated working pressure

    pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa;

    DN200~DN1200: ≤ 1.0MPa

    Flow rate range

    0.3~15m/s

    Measured fluid conductivity

    ≥5μs/cm liquid

    Output

    4~20mA / 4~20mA + Hart

    Electrode material

    316L, titanium (Ti), tantalum (Ta), Hastelloy (H),

    Platinum (Pt) or other special electrode materials

    Working power supply

    85~265VAC / 24VDC / Battery

    Straight pipe length

    pipe: ≥ 5DN in the upper reaches, downstream of greater

    than or equal to 2DN

    Connections

    Flange

    Protection grade

    standard: IP65; IP68(optional)

    Explosion-proof mark

    mdllBT4


    Detailed Images

    Usa Standard Atex Water Sewage Electromagnetic Flow Meter For Liquid PropaneUsa Standard Atex Water Sewage Electromagnetic Flow Meter For Liquid PropaneUsa Standard Atex Water Sewage Electromagnetic Flow Meter For Liquid Propane


    Precautions
    1. Try to avoid ferromagnetic objects and equipment with strong electromagnetic fields, so as to avoid the magnetic field affecting the working magnetic field of the sensor and the flow signal.
    2. should be installed in a dry and ventilated place, to avoid sun and rain, the ambient temperature should be -20 ~ +60 ° C, relative humidity is less than 85%.
    3. There should be plenty of space around the flowmeter for easy installation and maintenance.

    Installation requirements
    The measurement principle of the electromagnetic flowmeter is that it does not depend on the flow characteristics. If there is a certain turbulence and vortex inside the pipeline, it will be generated in the non-measurement zone (such as elbow, tangential current limit or half-opening shut-off valve upstream). Measurement is irrelevant. If steady-state eddy currents in the measurement zone affect the stability of the measurement and the accuracy of the measurement, then some measures should be taken to stabilize the flow rate distribution:
    A. Increase the length of the straight pipe before and after.
    B. Using a flow stabilizer.
    C. Reduce a section of the measuring point.


    Quality Usa Standard Atex Water Sewage Electromagnetic Flow Meter For Liquid Propane for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sichuan Vacorda Instruments Manufacturing Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)