Sign In | Join Free | My himfr.com
Home > Electromagnetic Flow Meter >

Industry 4-20mA Integrated Magnetic Flow Meter Facory With HART

    Buy cheap Industry 4-20mA Integrated Magnetic Flow Meter Facory With HART from wholesalers
     
    Buy cheap Industry 4-20mA Integrated Magnetic Flow Meter Facory With HART from wholesalers
    • Buy cheap Industry 4-20mA Integrated Magnetic Flow Meter Facory With HART from wholesalers
    • Buy cheap Industry 4-20mA Integrated Magnetic Flow Meter Facory With HART from wholesalers
    • Buy cheap Industry 4-20mA Integrated Magnetic Flow Meter Facory With HART from wholesalers
    • Buy cheap Industry 4-20mA Integrated Magnetic Flow Meter Facory With HART from wholesalers
    • Buy cheap Industry 4-20mA Integrated Magnetic Flow Meter Facory With HART from wholesalers

    Industry 4-20mA Integrated Magnetic Flow Meter Facory With HART

    Ask Lasest Price
    Price : USD200-500/PCS
    Payment Terms : L/C, T/T, Western Union
    Delivery Time : 5-15 working days
    Brand Name : Vacorda
    Model Number : HKLD
    Certification : ISO9001:2000/CE
    • Product Details
    • Company Profile

    Industry 4-20mA Integrated Magnetic Flow Meter Facory With HART

    Industry 4-20 ma integrated magnetic flow meter facory with HART

    Product Description

    HKLD intelligent electromagnetic flowmeter is a kind of fully intelligent electromagnetic flowmeter developed by our company with advanced technology at home and abroad. Its Chinese electromagnetic converter core uses high-speed central processing unit. The calculation speed is very fast, the accuracy is high, and the measurement performance is reliable. The circuit design of the converter adopts international advanced technology, the input impedance is up to 10 ohms, the CMRR is better than 100db, and the rejection ability for external interference and 60Hz/50Hz interference is better than 90db. It can measure the flow rate of fluid medium with lower conductivity.



    Application:
    Due to its unique advantages, it is widely used in the fields of petroleum, chemical industry, steel, light industry, sewage processing, environmental protection, water conservancy project and pharmacy to measure the volume flow of the conducted liquid mediums, such as acid, alkali, salt solution and so on.

    Technical parameters:

    PTFE Lined Pipe

    10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600

    Rubber Lined Pipe

    40, 50, 65, 80, 100, 125, 150, 200, 300, 350, 400, 500, 600, 800, 1000, 1200, note: special specifications can be customized

    Flow direction

    positive and negative, net flows Turndown

    Measuring range ratio

    150:1

    Repeatability error

    +/-0.1%

    Accuracy

    piped: 0.5 class, 1.0 class

    Measured medium temperature

    Common rubber lining: -20~+60 ° c

    High temperature rubber lining: -20~+90 ° c

    PTFE lining: -30~+100 ° c

    High temperature vinyl lining: -30~+180 ° c

    Rated working pressure

    pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa;
    DN200~DN1200: ≤ 1.0MPa

    Flow measuring range

    flow measuring range corresponding to flow rate range is 0.3~15m/s

    Measured fluid conductivity

    5μs/cm (Most with water as the composition of the medium, its conductivity in the range 200~800 Mu s/cm, optional solenoid flow)

    Output

    Current:4~20mADC (isolation), pulse frequency 0~1kHz, OCT photoelectric isolation, external power ≤ 35VDC, breakover, collector Max 25mA

    Load resistance

    < 600 Ω

    Electrode material

    316L, titanium (Ti), tantalum (Ta), Hastelloy, (h), Platinum (Pt) or other special electrode materials

    Protection grade

    standard: IP65; IP68

    Working power supply

    85~265VAC 45~63HZ

    Straight pipe length

    pipe: ≥ 5DN in the upper reaches, downstream of greater than or equal to 2DN

    Connections

    flow meter connected to the piping is used between flanges, flange connection dimensions comply with GB9119-88 requirements.

    Explosion-proof mark

    mdllBT4

    environment temperature

    -25 ° c ~=60 ° c

    Relative humidity

    5%~95%

    Total power consumption

    <20W

    Detailed Images
    Industry 4-20mA Integrated Magnetic Flow Meter Facory With HART

    Industry 4-20mA Integrated Magnetic Flow Meter Facory With HARTIndustry 4-20mA Integrated Magnetic Flow Meter Facory With HART

    Industry 4-20mA Integrated Magnetic Flow Meter Facory With HART

    Electromagnetic flowmeter as an effectively measure the volume flow rate of conductive media, its main components include sensors, flow conversion and processing instruments. And its main feature is that it has no throttling flow-resisting parts, it is not easy to block, has good corrosion resistance, and has a wide range of applicable media. The measurement accuracy is not affected by physical parameters such as temperature, viscosity, density, pressure, and specific gravity of the measured medium. A certain conductivity range is independent of the type of liquid being calibrated.


    As a most widely used flow instrument, electromagnetic flowmeters are commonly used to measure conductive liquids such as tap water, sewage, and seawater. Therefore, after running for a period of time, it is easy to contaminate the electrode or to precipitate and foul in the measurement tube wall. So the adhered scale layer in the measuring tube of the electromagnetic flowmeter should be removed in time, otherwise the instrument may not work properly.

    Quality Industry 4-20mA Integrated Magnetic Flow Meter Facory With HART for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sichuan Vacorda Instruments Manufacturing Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)